MEDsan — Home of the iSelfTest Learn more

Shop our latest products! Learn more

MEDsan

PoC-1 qPCR

$25,000.00 $39,000.00
Number of Instruments

Technical Data

Shipping & Return

Once your order has been placed with us, we will prepare and ship your package within 1-2 business days.

Delivery within the Continental U.S. is about 3-10 business days.

Any unopened items that are still sealed can be returned to us within 30 days. Please note that no returns will be accepted for personal care items and products that are subject to special storage, i.e. refrigeration.

Please contact us for any returns prior to sending the shipment to us. Any unauthorized returns cannot be processed.

PoC Automated Nucleic Acid Extraction and PCR System
                                                                     


Nodus-Gene series automated nucleic acid extraction and PCR system includes three models: Nodus-Gene 1, Nodus-Gene 2 and Nodus-Gene 4, which can handle 1, 2 and 4 samples at the same time. Various models can be freely combined, and up to 16 samples can be extracted and tested at the same time.

The instrument includes 4 fluorescence detection channels, which can achieve multiple detection projects of one sample at the same time, and strict self-checking mechanism ensures the accuracy of the results. In addition, instrument innovatively adds a quantitative detection function, which can freely select the output qualitative or quantitative detection results according to actual needs.

Sample In - Result Out!

Manual Operation of only ≤2 min necessary.

Areas of Application
  • CDC
  • Tumor Screening
  • Infection Detection
  • Prenatal Testing
  • Forensic Identification
  • Pet Hospital
  • Food Safety Testing

HD Touchscreen Connectivity

The instrument is small and flexible with 10.5-inch touch screen. Equipped with intuitive interface and stable operation software, it's an ideal choice for on-site fast detection!

Reagent Cartridge Kit

The cartridge consists of four parts: Base, Reaction Chamber, PCR reaction area and Top Cover. The function relies on the rotation of the bottom piston valve to achieve the liquid transfer between different chambers.

  1. Add samples and magnetic beads in the sample chamber to perform the lysis and binding steps of the nucleic acid extraction.
  2. Then, the nucleic acid is washed and purified three times in the washing chambers and eluted into the elution chamber.
  3. Finally, the reagents are mixed in the PCR reaction area to perform the PCR amplification reaction.


Features
  • Closed Detection System
    Separate disposable cartridges, each sample is evaluated in an independent cartridge. This prevents contamination between the individual samples and the seal additionally prevents contamination from aerosol leakage.
  • Automated Detection
    By using freeze-drying technology, the reagents for nucleic acid extraction and the PCR reaction are pre-prepared directly in the cartridge. Manual addition of the reagents is no longer necessary. The user only needs to add the samples and magnetic beads. The manual operation time is ≤ 2 min, truly realizing “samples in, results out”.
  • Multi-Channel Detection
    4 detection channels are available for each sample. The excitation-emission wavelengths are 470-510 nm, 530-565 nm, 585-620 nm and 630-665 nm, respectively. Multiple channels can be detected at the same time.
  • Intuitive  & Open Software
    Visualized interface and user authorization management. The administrator has the highest authority. The automated nucleic acid extraction and PCR system has good adaptability and high software openness. Adopting an open software design, which can be adapted to all kinds of magnetic bead extraction and detection kits on the market.
  • Multiple Detection Types
    Depending on customer requirements, three PCR types are available: qualitative, quantitative and SNP. The quantitative results are directly determined by the number of nucleic acid copies according to the standard curve, in order to obtain an accurate evaluation of the samples.

 

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

1, 2, 4, 8, 12 & 16 Machines

Looking for qPCR Test Machines with several Wells?

MEDsan's line of SBMS qPCR Test Machines range from 24, 96, and 384 Well Testing.

MEDsan

PoC-1 qPCR

From $25,000.00 $39,000.00

PoC Automated Nucleic Acid Extraction and PCR System
                                                                     


Nodus-Gene series automated nucleic acid extraction and PCR system includes three models: Nodus-Gene 1, Nodus-Gene 2 and Nodus-Gene 4, which can handle 1, 2 and 4 samples at the same time. Various models can be freely combined, and up to 16 samples can be extracted and tested at the same time.

The instrument includes 4 fluorescence detection channels, which can achieve multiple detection projects of one sample at the same time, and strict self-checking mechanism ensures the accuracy of the results. In addition, instrument innovatively adds a quantitative detection function, which can freely select the output qualitative or quantitative detection results according to actual needs.

Sample In - Result Out!

Manual Operation of only ≤2 min necessary.

Areas of Application
HD Touchscreen Connectivity

The instrument is small and flexible with 10.5-inch touch screen. Equipped with intuitive interface and stable operation software, it's an ideal choice for on-site fast detection!

Reagent Cartridge Kit

The cartridge consists of four parts: Base, Reaction Chamber, PCR reaction area and Top Cover. The function relies on the rotation of the bottom piston valve to achieve the liquid transfer between different chambers.

  1. Add samples and magnetic beads in the sample chamber to perform the lysis and binding steps of the nucleic acid extraction.
  2. Then, the nucleic acid is washed and purified three times in the washing chambers and eluted into the elution chamber.
  3. Finally, the reagents are mixed in the PCR reaction area to perform the PCR amplification reaction.


Features

 

Number of Instruments

  • 1x Machine
  • 2x Machine
  • 4x Machine
  • 8x Machine
  • 16x Machine
View product